STORING PROPANE CYLINDERS:
1. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust
cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may
result in leakage of propane.
2. Store all propane cylinders outdoors in a well-ventilated area.
3. Do not store cylinders in direct sunlight or near a source of heat or combustion.
4. Propane cylinders must be REMOVED from your grill; when the grill is to be stored indoors.
5. Keep all propane tanks out of reach of children.
6. If your grill is stored outside, the propane tank may be left connected to the grill. Turn off propane tank
valve when grill is not in use.
1 Never insert any foreign objects in valve outlet, as this may cause leaks.
2 Do NOT connect this grill to unregulated Propane systems such as in a
motor home or camper trailer. System pressure MUST be regulated
before hook up.
3 Do NOT use this grill until leak tests have been completed.
4. If a gas leak is detected and cannot be stopped, call the fire department.
FUEL TYPE:
The following instructions are for Natural Gas configured grills ONLY. Operating Pressure = 4" WC.

INSTALLATION CODES:

Please refer to page 2, item #1 of this manual.
CART: CONNECTING THE NATURAL GAS HOSE:
1. Use only the natural gas hose supplied with your Natural Gas configured grill.
2. Install the supplied hose onto the flare nut nipple on the fuel regulator, located on the RH inner side of the
pedestal. DO NOT USE SEALANT of any kind. Tighten using a ¾" open end wrench or a crescent
wrench. Hold the regulator nut with a second wrench while tightening.
3. A female quick release is included with the grill. Install it onto the homeowner's preexisting natural gas
quick release box. NOTE; pipe dope or Gas Rated Teflon tape must be used to seal the threads at this
connection.
4. Check supply pressure to ensure that incoming pressure to the inlet side of the 4" WC NG Regulator on
the NG appliance is no higher than 7" Water Column.
5. Use a soapy water solution to check all connections for leaks before lighting grill. If a leak is found DO
NOT use the grill. Turn gas off and call a professional gas fitter to repair the leak.
BUILT IN NATURAL GAS HOOK-UP: (Fig. 12)
1. The piping up to the gas grill is the responsibility of the installer and piping should be located as shown
below.
2. The connector must not pass through a wall, floor, ceiling or partition, and is protected from damage.
3. Do not use a rubber hose to connect the unit to the outlet 4"WC regulator. An approved appliance to the
stainless steel flex hose must be used.
!WARNING!

Natural Gas Connection: