DITEC E1 Notice D'installation page 16

Masquer les pouces Voir aussi pour E1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
8.
EXAMPLE OF APPLICATION FOR BARRIERS
GB
(Fig. 8.1) When control panel E1 is used for barriers opera-
tions:
-
set RF=5 (MAX);
-
set TM=MAX;
-
connect opening and closing limit switches N.C. contacts
to plug 12-0-11.
(Fig. 8.2) Control N.C. 1-6 (safety stop) can be changed into
control N.O. 1-4 (closing) setting 6→4=OFF.
To have the barrier close again soon after transit between the
photocells (or other safeties connected to 1-8), set DIP3=OFF.
(Fig. 8.3) Select the proper opening direction by means of
DIP2.
9.
EXAMPLE OF APPLICATION FOR BALANCED UP-AND-OVER DOORS (E1BOX)
Connect button P1 to terminals 1-5 as shown in fig. 9.1.
If the balanced up-and-over door needs two motors, connect
the motors as shown in fig. 9.2
E1 - IP1853
12 0 11
SO 6 4
12 11 0 1 5 6 8 9
DIP2=OFF
L N
230 V~
25 W
16
RF=MAX
TM=MAX
12 11 0 1 5 6 8 9
DIP3=OFF
ON
OFF
1 2 3 4
DIP2=ON
P1
12 11 0 1 5 6 8 9
C U W V
U W V
U W V
M
M
1~
1~
230 V~
25 W
Fig. 8.1
Fig. 8.2
Fig. 8.3
Fig. 9.1
Fig. 9.2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E1j

Table des Matières