General Safety Precautions; Ec Declaration Of Conformity; Technical Details; Applications - DITEC E1 Notice D'installation

Masquer les pouces Voir aussi pour E1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18

GENERAL SAFETY PRECAUTIONS

GB
This installation manual is intended for professionally
competent personnel only.
The installation, the power connections and the settings must
be completed in conformity with Good Working Methods and
with the regulations in force. Before installing the product,
carefully read the instructions. Bad installation could be ha-
zardous.
The packaging materials (plastic, polystyrene, etc.) should not
be discarded in the environment or left within reach of children,
as these are a potential source of hazard. Before beginning the
installation check that the product is in perfect condition.
Do not install the product in explosive areas and atmospheres:
the presence of flammable gas or fumes represents a serious
threat to safety.
The safety devices (photocells, sensitive edges, emergency
stop, etc.) must be installed taking into account: the provisions
and the directives in force, Good Working Methods, the instal-
lation area, the functional logic of the system and the forces
developed by the motorised door or gate.
Before making power connections, check that the rating
corresponds to that of the mains supply A multipolar di-
sconnection switch with a contact opening gap of at least 3 mm
must be included in the mains supply. Check that upstream of
the electrical installation an adequate residual current circuit
breaker and an overcurrent cut out are fitted. When requested,
connect the motorised door or gate to an effective earthing
system carried out as indicated by current safety regulations.
During installation, maintenance and repair operations, cut
off the power supply before opening the cover to access the
electrical parts.
To handle electronic parts, wear earthed antistatic con-
ductive bracelets. The manufacturer of the motorisation
declines all responsibility in the event of components which
are not compatible with the safe and correct operation of the
product. For repairs or replacements of products only original
spare parts must be used.

INSTALLATION WARNING

Secure the control panel permanently. Drill a hole into the lower
side of the container so as to run the cables through it. Secure
the cables, if they are accessible, by means of appropriate
gland plates (not provided by us). Keep the line and motor con-
ductors separate (at least 8 mm) from the control conductors at
the terminal board connection points (for example, by means
of clamps). Connect the line and motor protection conductors
(yellow-green) by means of the transformer and control panel
using the clamp provided. At the end of the installation to close
again the container.
E1 - IP1853

EC DECLARATION OF CONFORMITY

Manufacturer:
DITEC S.p.A.
Address:
via Mons. Banfi, 3
21042 Caronno P.lla (VA) – ITALY
Herewith declares that the control panel E1 (with receiver 433.92
MHz) is in conformity with the provisions of the following EC
directives:
Low Voltage Directive 2006/95/EEC;
EMC Directive 2004/108/EEC;
R&TTE Directive 1999/5/EC.
Caronno Pertusella,
18-10-2002

TECHNICAL DETAILS

Power supply
Fuse F1
Motor output
230 V~ / 5 A max 120 V~ / 6,3 A max
Accessories power
supply
Temperature
Protection degree
(E1)
Protection degree
(E1BOX)
Radio frequency
Memorizable radio
codes

APPLICATIONS

E1
E1BOX
10
Fermo Bressanini
(President)
E1
E1J
230 V~ / 50Hz
120 V~ / 60Hz
F5A
F6,3A
24 V= / 0,5 A
24 V= / 0,5 A
-20° C / +55° C
-20° C / +55° C
IP55
IP55
IP10
IP10
433,92 MHz
433,92 MHz
200
200

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E1j

Table des Matières