K.M080.. / K.M100H.. / K.M150L.. / K.W080.. / K.W100L.. / K.T040H.. / K.D200N..+0075..
3.
EXAMPLE OF ...X... - MOTOR DATA PLATE (for flameproof models only)
CE
II 2G Ex db h IIB T4 Gb -
I M2 Ex db h I Mb
TÜV IT20 ATEX033X
Production date

MOTOR TYPE

Complete motor code
GB
Serial N°
P
[kW]
Motor power delivery
2
f [Hz]
Frequency
3 Ph ~
Threephase a.c. power supply
n [min -1]
Rotation speed
S1
Continuos service with motor completely submerged
I.E.C. 60034-1
Standards used to establish the electrical characteristics
4.
EXAMPLE OF A CABLE CLAMP DATA PLATE (for flameproof models only)
Never ever use the power supply
cable to move the pump
5.

PUMP CODING

Example : KCM100HA + 005141N1 / #####
Series
50 Hz ( S=60 Hz )
Single-channel impeller ( 1 )
DNm delivery port
Type / hydraulic size motor (electric centering)
Impeller diameter
Motor output power code (50 Hz) x 10 (0051=5,1 kW)
Nº Poles
Powering voltage code
Standard electric pump (X = flameproof)
Generational code
Miscellaneous specialties
Motor code match
( 1 )
Twin-channel impeller
Single-channel impeller
6.

MOTOR CODING

(The motor data plate is only necessary on flameproof electric pumps)
Example: KC005141H112N1 / ####
Series
50 Hz ( S=60 Hz )
Motor output power code x 10 (0051=5,1 kW)
N° Poles
Powering voltage code
Type / hydraulic size motor (electric centering)
Surface motor frame size (ref. surface motor)
Standard motor (X = flameproof)
Generational code
Miscellaneous specialties
Associations with complete electric pump code
18
Flameproof classification and certification (see paragraph 8)
Do not use the feeding cable
to move the pump
100
K
C
M
H
: D
Vortex impeller
: M
Hydraulics with shredder
K
C
0051
4
1
U [V]
I [A]
cosϕ
I. Cl.
S3
Tightening torque
8 Nm
A
+
0051
4 1
: W
: T
H
112
N
1
3
Mains voltage / Type of connection
Rated power draw
Power factor
Motor insulation category
Intermittent service (in 10 minute cycles)
Cable clamp screw
torque 8 Nm (0.8 Kgm)
#####
N
1
3
#####
Caprari S.p.A.