Commissioning
Important codes for quick commissioning
Code
No.
Name
C0034
Range of
*
setpoint
v
selection
Application I/O
(A)
uSEr
X3/1U, X3/1I
1
2
X3/2U, X3/2I
C0037
JOG1
C0038
JOG2
C0039
JOG3
C0050
Output
*
frequency
(MCTRL1−NOUT)
uSEr
C0087
Rated motor
speed
C0088
Rated motor
current
C0089
Rated motor
frequency
C0090
Rated motor
voltage
Motor cos 
C0091
C0119
Configuration
v
of motor
temperature
monitoring (PTC
input) / earth
fault detection
152
Possible settings
Lenze
Selection
0
0
Unipolar voltage 0 ... 5 V / 0 ... 10 V
1
Bipolar voltage −10 V ... +10 V
2
Current 0 ... 20 mA
3
Current 4 ... 20 mA
4
Current 4 ... 20 mA open−circuit monitored Reversal of rotation direction only
20.00
−650.00
30.00
−650.00
40.00
−650.00
−650.00
à
300
à
0.0
50
10
à
50
à
0.40
0
0
PTC input inactive
1
PTC input active,
TRIP effected
2
PTC input active,
warning effected
3
PTC input inactive
4
PTC input active,
TRIP effected
5
PTC input active,
warning effected
{0.02 Hz}
650.00
{0.02 Hz}
650.00
{0.02 Hz}
650.00
{Hz}
650.00
{1 rpm}
16000
0.1 (A)
650.0
{1 Hz}
{1 V}
{0.1}
Earth fault
detection active
Earth fault
detection inactive
l
IMPORTANT
Observe jumper position of the
function module!
Minimum output frequency (C0010)
not effective
Reversal of rotation direction only
possible with a digital signal.
possible with a digital signal.
TRIP Sd5 at I < 4 mA
JOG = fixed setpoint
Additional fixed setpoints ðC0440
Read only: Output frequency without
slip compensation
à
Device−dependent
à
Device−dependent
0.0 ... 2.0 x rated output current of
the controller
960
à
500
230 V for 230 V controllers,
400 V for 400 V controllers
à
1.0
Device−dependent
l
Configure signal output in C0415
l
If several parameter sets are
used, monitoring has to be set
separately for every parameter
set.
l
Deactivate earth fault detection
if the earth fault detection is
actuated unintentionally.
l
If the earth fault detection is
activated, the motor starts with a
delay of approx. 40 ms after
controller enable has been set.
EDK82EV222 DE/EN/FR 13.0