Important Safety Instructions - Milwaukee M12 Fuel Manuel De L'utilisateur

Aspirareur de détritus secs et liquides de 6,1 l (1,6 gal)
Masquer les pouces Voir aussi pour M12 Fuel:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT SAFETY INSTRUCTIONS

WARNING
WHEN USING AN ELECTRICAL VACUUM, BASIC
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, IN-
CLUDING THE FOLLOWING: READ ALL INSTRUCTIONS BEFORE USING
VACUUM. BEFORE USING THE VACUUM, READ THIS OPERATOR'S MAN-
UAL, BATTERY PACK AND CHARGER OPERATOR'S MANUALS, AND ALL
LABELS ON THE VACUUM, BATTERY PACK, AND CHARGER. FAILURE TO
FOLLOW THE WARNINGS AND INSTRUCTIONS MAY RESULT IN ELEC-
TRIC SHOCK, FIRE AND/OR SERIOUS INJURY.
WORK AREA SAFETY
• Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
• Vacuums have motors and other parts that can
produce sparks during normal use. Do not use
within 30 feet of areas where explosive materials
may be present (such as gasoline pumps and places
where liquids like paint thinners, cleaners, solvents,
etc. are stored).
• Do not use in the presence of explosive dust,
liquids or vapors.
• Do not use where oxygen or anesthetics are used.
• Do not allow to be used as a toy. Close attention
is necessary when used by or near children.
• Use extra care when using on stairs.
ELECTRICAL SAFETY
• Do not handle battery pack or vacuum with wet
hands.
PERSONAL SAFETY
• STAY ALERT. Watch what you are doing and use
common sense. Do not use vacuum when you are
tired, distracted or under the influence of drugs,
alcohol or medication causing diminished control.
• The operation of a vacuum can result in foreign
objects being blown into eyes, which can result
in eye damage. Always wear safety goggles or
glasses with side shields when operating vacuum.
• Wear a dust mask or use an OSHA compliant
vacuum solution when working in dusty situations.
Dust particles can harm your lungs.
• Avoid accidental starting. Ensure the switch is
in the off-position before inserting battery pack.
Inserting battery pack in vacuum that has the switch
on invites accidents.
• Do not overreach. Keep proper footing and bal-
ance at all times. This enables better control of the
vacuum in unexpected situations.
• Keep hair, loose clothing, fingers, and all parts
of body away from openings and moving parts.
• Use only as described in this manual. Use only
manufacturer's recommended attachments.
• Prevent unintentional starting. Ensure the switch
is in the off-position before connecting to power
source and/or battery pack, picking up or carrying
the tool. Carrying power tools with your finger on
the switch or energizing power tools that have the
switch on invites accidents.
VACUUM USE AND CARE
• Do not use without dust canister and/or filter in
place.
• Do not use to pick up flammable or combustible
liquids such as gasoline or use in areas where they
may be present.
• Do not pick up anything that is burning or smok-
ing such as cigarettes, matches, or hot ashes.
• Do not pick up soot, cement, plaster or drywall
dust without filter in place. These are very fine
particles that may affect the performance of the
motor or be exhausted back into the air.
•This product is suitable for collection of silica
dust when used in accordance with these in-
structions. To reduce the risk of health hazards
from other vapors or dust, do not vacuum
carcinogenic, toxic or hazardous materials
such as asbestos, arsenic, barium, beryllium, lead,
pesticides or other health endangered materials.
• Use special care when emptying heavily loaded
tanks.
• To avoid spontaneous combustion, empty dust
box after each use.
• Do not leave vacuum unattended when battery
pack is installed. Remove battery pack when not
in use and before servicing.
• Disconnect the battery pack from the appliance
before making any adjustments, changing ac-
cessories, or storing appliance. Such preventive
safety measures reduce the risk of starting the ap-
pliance accidentally.
• Do not put any object into openings. Do not use
with any opening blocked; keep free of dust, lint,
hair, and anything else that may reduce air flow.
• Maintain vacuum. Check for misalignment or
binding of moving parts, breakage of parts and
any other condition that may affect the vacuum's
operation. If damaged, have the vacuum repaired
before use. Many accidents are caused by poorly
maintained tools.
BATTERY TOOL USE AND CARE
• Recharge only with the charger specified by the
manufacturer. A charger that is suitable for one type
of battery pack may create a risk of fire when used
with another battery pack.
• Use power tools only with specifically designated
battery packs. Use of any other battery packs may
create a risk of injury and fire.
• When battery pack is not in use, keep it away
from other metal objects, like paper clips, coins,
keys, nails, screws or other small metal objects,
that can make a connection from one terminal
to another. Shorting the battery terminals together
may cause burns or a fire.
• Under abusive conditions, liquid may be ejected
from the battery; avoid contact. If contact ac-
cidentally occurs, flush with water. If liquid
contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation
or burns.
• Do not use a battery pack or tool that is dam-
aged or modified. Damaged or modified batteries
may exhibit unpredictable behavior resulting in fire,
explosion or risk of injury.
2
• Do not expose a battery pack or tool to fire or
excessive temperature. Exposure to fire or tem-
perature above 265°F (130°C) may cause explosion.
• Follow all charging instructions and do not charge
the battery pack or tool outside the temperature
range specified in the instructions. Charging
improperly or at temperatures outside the specified
range may damage the battery and increase the risk
of fire.
SERVICE
• Have your power tool serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the power
tool is maintained.
• Do not modify or attempt to repair the appliance
or the battery pack (as applicable) except as
indicated in the instructions for use and care.
SPECIFIC SAFETY RULES FOR
WET/DRY VACUUM
• Never use vacuum without tank and filter prop-
erly installed.
• Wear ear protectors. Exposure to noise can cause
hearing loss.
WARNING
To reduce the risk of
injury, when working
in dusty situations, wear appropriate respira-
tory protection or use an OSHA compliant dust
extraction solution.
• Always use common sense and be cautious when
using tools. It is not possible to anticipate every
situation that could result in a dangerous outcome.
Do not use this tool if you do not understand these
operating instructions or you feel the work is beyond
your capability; contact Milwaukee Tool or a trained
professional for additional information or training.
• Maintain labels and nameplates. These carry
important information. If unreadable or missing,
contact a MILWAUKEE service facility for a free
replacement.
WARNING
Some dust created by
power sanding, sawing,
grinding, drilling, and other construction activities
contains chemicals known to cause cancer, birth
defects or other reproductive harm. Some examples
of these chemicals are:
• lead from lead-based paint
• crystalline silica from bricks and cement and other
masonry products, and
• arsenic and chromium from chemically-treated
lumber.
Your risk from these exposures varies, depending on
how often you do this type of work. To reduce your
exposure to these chemicals: work in a well ventilated
area, and work with approved safety equipment, such
as those dust masks that are specially designed to
filter out microscopic particles.
READ AND SAVE
ALL
INSTRUCTIONS
FOR FUTURE USE
FOR HOUSEHOLD OR COMMERCIAL USE.
SYMBOLOGY
Volts
Direct Current
Read operator's manual
Wear eye protection
Do not step
Unlock
Lock
UL Listing for Canada and U.S.
C
US
SPECIFICATIONS
Cat. No. ..................................................... 0960-20
Volts............................................................12V DC
Battery Type .................................................M12™
Charger Type................................................M12™
Max Air Flow ...............................................45 CFM
Max Suction ............................................. 42 inH2O
Capacity...........................................1.6 Gal. (6.1 L)
Recommended Ambient
Operating Temperature ......................0°F to 125°F
Foam Filter .......................................... 49-90-2015
Washable HEPA Filter ........................ 49-90-1900
Fleece Dust Bag.................................. 49-90-2016
Round Brush Tool .............................. 49-90-2017
Power Tool Adapter
............................
49-90-2018
3

Publicité

Table des Matières
loading

Table des Matières