Benning CM 10-PV Notice D'emploi page 33

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

rate. Thus, an additional error occurs for the following crest factors:
crest factor from 1.0 to 2.0 additional error + 3.0 %
crest factor from 2.0 to 2.5 additional error + 5.0 %
crest factor from 2.5 to 3.0 additional error + 7.0 %
Maximum crest factor of the measuring signal:
crest faktor 3.0 @ 3000 digits
crest faktor 2.0 @ 4500 digits
crest faktor 1.5 @ 6000 digits
Measured values < 20 digits are set to 0 on the digital display K .
Square-wave signals are not specified.
HFR function (low-pass filter)
additional error for functions V
± 4 % with regard to the specified measuring accuracy (45 Hz to 200 Hz)
Limiting frequency fg (- 3 dB): 800 Hz
7.1 Voltage ranges (V AC, V DC)
Function
Measuring
V AC
600.0 mV
V DC
Overload protection:
Input resistance:
7.2 Voltage ranges (PV) via BENNING TA PV measuring adapter
Function
Measuring
PV V DC
PV V AC
Overload protection:
Input resistance:
7.3 Current ranges (A
Function
Measuring
A AC
[1] [2]
A DC
[1]
Measured values below < 5 A, plus 10 digits
[1]
Frequency > 100 Hz, plus 1 %
[2]
Overload protection:
Frequency range:
Positioning error:
7.3.1
Microampere current ranges (µA
Function
Measuring
400.0 µA
µA
AC/DC
Overload protection:
Input resistance:
Frequency range:
03/ 2020
AC
Resolution
range
600.0 V
0.1 V
1000 V
1 V
0.1 mV
600.0 V
0.1 V
1000 V
1 V
1000 V
DC: 10 MΩ, AC: 10 MΩ II < 100 pF
Resolution
range
600.0 V
0.1 V
2000 V
1 V
600.0 V
0.1 V
1500 V
1 V
1000 V
DC: 10 MΩ, AC: 10 MΩ II < 100 pF
)
AC/DC
Resolution
range
60.00 A
0.01 A
600.0 A
0.1 A
60.00 A
0.01 A
600.0 A
0.1 A
600 A
45 Hz - 400 Hz (sine)
± 1 % of the measured value
Resolution
range
0.1 µA
4000 µA
1 µA
1000 V
ca. 3 kΩ
45 Hz - 400 Hz (sine)
BENNING CM 10–PV
, A
and
(flexible AC current transformer)
AC
± (1.0 % + 7 digits), 45 Hz - 400 Hz, sine
AC/DC
± (2.0 % + 7 digits). 45 Hz - 400 Hz. sine
AC/DC
AC/DC
)
AC/DC
AC/DC
Measurement accuracy
± (0.7 % + 7 digits)
± (0.7 % + 4 digits)
Measurement accuracy
± (2.0 % + 7 digits)
Measurement accuracy
± 2.0 % + 7 digits
± 2.0 % + 7 digits
Measurement accuracy
± 1.0 % + 5 digits
33

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

044683

Table des Matières