A. Spécification pour DeviceNet
Attribute
Access
1
Get
2
Get
3
Get
4
Get
5
Get
6
Get
7
Get
8
Get
9
Get/Set
12
Get/Set
13
Get
14
Get
15
Get
16
Get
A-20
Connection Object, Instance 2 Attributes (Polled I/O
Message)
Name
State
Instance Type
Transport Class Trigger
Production Connection ID
Consumed Connection ID
Initial Comm. Char.
Production Size
Consumed Size
Expected Packet Rate
Timeout Action
Prod. Path Length
Production Path
Log. Seg., Class
Class Number
Log.Seg., Instance
Instance Number
Log.Seg., Attribute
Attribute Number
Cons. Path Length
Consumed Path
Log. Seg., Class
Class Number
Type
Value
(voir en 1 )
UINT
UINT
1 = I/O Message
UINT
0x82
(voir en 2 )
UINT
(voir en 2 )
UINT
UINT
0x1
UINT
1
UINT
1
UINT
Dependent on
application
(voir en 3 )
UINT
UINT
6
STRUCT OF
UINT
0x20
UINT
0x04 (Assembly)
UINT
0x24
UINT
1, 3, 5, 7 dependent on
application
UINT
0x30
UINT
0x03
UINT
6
STRUCT OF
UINT
0x20
UINT
0x04 (Assembly)
Festo P.BE-SPC200-COM-CANDN-FR fr 0012NH