Hitachi C 18DL Mode D'emploi page 11

Masquer les pouces Voir aussi pour C 18DL:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
Do not use the electrical cord if
damaged. Have it repaired
immediately.
2.
Insert the battery to the battery charger.
Insert the battery into the battery charger as shown
in Fig. 6. Make sure it contacts the bottom of the
battery charger.
Charge status lamp
(red)
Overheat lamp
(green)
Before
Charge
charging
status
lamp (RED)
While
charging
Charging
complete
Charging
impossible
Overheat
Overheat
lamp
standby
(GREEN)
NOTE: When standby for cooling battery, UC18YRL
cools the overheated battery by cooling fan.
Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in the table below, and batteries that
have become hot should be cooled for a while
before being recharged.
Battery
Fig. 6
Indications of the pilot lamp
Blinks
Lights for 0.5 seconds. Does not light
(RED)
for 0.5 seconds. (off for 0.5 seconds)
Lights
Lights continuously
(RED)
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(RED)
Lights for 0.1 seconds. Does not light
Flickers
for 0.1 seconds. (off for 0.1 seconds)
(RED)
Lights
Lights continuously
(GREEN)
3.
Charging
When the battery is connected to the battery
charger, charging will commence and the pilot
lamp will light in red. (See Table 2)
NOTE: If the pilot lamp flikers in red, pull out the plug
from the receptacle and check if the battery is
properly mounted.
When the battery is fully charged, the pilot lamp
will bilink in red slowly. (At 1-second intervals) (See
Table 2)
Table 2
Rechargeable
batteries
EBM1830
4.
Disconnect battery charger from the receptacle.
English
Malfunction in the
battery or the charger
Battery
overheated.
Unable
to
(Charging will commence
when battery cools).
Table 3
Temperatures at which the
battery can be recharged
32°F — 122°F (0°C — 50°C)
charge
11