6. Interval operation
The fan can be automatically operated in adjustable intervals. The intervals can be adjusted via DIP-switches 5 and 6.
In interval mode, the set overrun time corresponds to the running time. Interval operation starts after the last switch-
off process. In interval mode, the set overrun time corresponds to the running time. Interval operation starts after the
last switch-off process. The required ventilation is superordinate to interval operation. In case of intermediate required
ventilation, the started interval time will be reset and restarted after deactivation.
The stage assignment is configured with DIP-switches 7 and 8 (see following table)
DIP-switch
7
8
off
off
on
off
off
on
on
on
7.1

Functional test - test mode:

When applying the supply voltage the fan is in the test mode for 1 minute. (Requirement: Factory setting of DIP-switch,
see wiring diagram SS-1081) In this case the activation delay and the overrun function is deactivated within the first
minute, or for a switching cycle.
Assignment of time function to stage
Np times
Time at lower stage
Time at higher stage
Time at both stages
12
Interval
Higher stage
Lower stage
Higher stage
Higher stage