2.5

Approvals

The facepieces in combination with self-contained breathing
apparatus, air line breathing apparatus, or canister have been
certified by NIOSH in compliance with title 42, Code of Federal
Regulations, Part 84. Only combinations that are approved by NIOSH
may be used (see "Approval Label" on Page 181 for masks with Rd40
connector for use with filters and canisters. Labels for SCBA sets can
be found in the Instructions for Use of the SCBA sets).
Furthermore, the facepieces are approved according to
EN 136:1998 CL.3+
In addition, they meet the flame engulfment requirements stipulated in
EN 137.
The Dräger FPS 7000 RA facepieces are also approved in Australia
and New Zealand according to AS/NZS 1716:2012.
Dräger FPS 7000
2.6
The facepieces have different markings:
Connector
Facepiece body
Size of facepiece
body
Size of nose cup
Visor
Rubber harness
Hairnet
(Use Instructions for NIOSH-approved full facepieces)

Type-identical identification marking

RA, P
EPDM or Si,
EN 136:1998 CL.3+
CExxxx (Notified Body in Europe)
S (small), M (medium), L (large)
1 (small), 2 (medium), 3 (large)
PC or APEC, F (fire brigade), according to
EN 166
A (ballistic protection class 190 m/s)
T (ballistic protection class at extreme
temperatures, tested at -22 °F to 140 °F
(-30 C° to +60 °C) with 190 m/s)
PCas or APECas (coated with scratch-
resistant material)
PCaf (coated with scratch-resistant material
on the outside, with anti-fog coating on the
inside)
EPDM, CR, or Si, M/L, or S
H
Description
171