Troubleshooting - Simer 3410P Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation
3410P – 1 HP
Discharge
Pressure
PSI (kPa)
5' (1.5)
10' (3)
10 (69)
55 (208)
49 (185)
15 (103)
51 (193)
46 (174)
20 (138)
45 (170)
42 (159)
25 (172)
38 (144)
35 (132)
30 (207)
31 (117)
28 (106)
35 (241)
23 (87)
19 (72)
40 (276)
17 (64)
13 (49)
45 (310)
50 (345)
All models except 3420P have discharge and suction size of 1-1/2" NPT. 3420P has 2" NPT suction and discharge.

Troubleshooting

Capacitor voltage may be hazardous. To discharge capacitor, hold insulated handle screwdriver BY THE HANDLE and short capacitor
terminals together. Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician.
SYMPTOM
POSSIBLE CAUSE(S)
Motor will not run
Disconnect switch is off
Fuse is blown or circuit breaker tripped
Starting switch is defective
Wires at motor are loose,
disconnected, or wired incorrectly
Motor runs hot and
Motor is wired incorrectly
overload kicks off or
Voltage is too low
motor does not run
and only hums
Motor runs but no
Pump in new installation did
water is delivered*
not pick up prime through:
1. Improper priming
2. Air leaks
* (Note: Stop pump;
3. Leaking foot valve or check valve
then check prime
4. Pipe size too small
before looking for
Pump has lost prime through:
other causes.
1. Air leaks
Unscrew priming
2. Water level below suction pipe inlet
plug and see if water
is in priming hole).
Impeller is plugged
Check valve or foot valve is stuck shut
Pipes are frozen
Foot valve and/or strainer are
buried in sand or mud
*Pump does not
Water level in well is lower than
deliver water to full
estimated
capacity
Steel piping (if used) is corroded or
limed, causing excess friction
Piping is too small in size
Pump not being supplied with
enough water
Pump leaks
Clamp loose
around clamp
For parts or assistance, call Simer Customer Service at
Performance Chart / GPM(LPM)
Height Of Pump Above Water / Feet (Meter)
15' (4.6)
20' (6.1)
5' (1.5)
48 (181)
45 (170)
67 (254)
45 (170)
44 (166)
66 (250)
39 (148)
37 (140)
61 (231)
32 (121)
29 (110)
55 (208)
24 (90)
20 (76)
48 (181)
16 (60)
11 (42)
39 (147)
8 (30)
33 (125)
18 (68)
3415P – 1-1/2 HP
10' (3)
15' (4.6)
20' (6.1)
61 (231)
56 (212)
46 (174)
58 (220)
55 (208)
45 (170)
56 (212)
54 (204)
44 (166)
52 (197)
51 (193)
43 (163)
45 (170)
44 (166)
37 (140)
37 (140)
34 (129)
28 (106)
27 (102)
20 (76)
11 (42)
14 (53)
8 (30)
CORRECTIVE ACTION
Be sure switch is on.
Replace fuse or reset circuit breaker.
DISCONNECT POWER; Replace starting switch.
Refer to instructions on wiring (Page 7). DISCONNECT POWER; check and
tighten all wiring.
Refer to instructions on wiring.
Check voltage being supplied to motor. Install heavier wiring if wire size is
too small (See Electrical / Wiring Chart).
In new installation:
1. Re-prime according to instructions.
2. Check all connections on suction line, with soapy water or
shaving cream.
3. Replace foot valve or check valve.
4. Re-pipe using size of suction and discharge ports on pump.
In installation already in use:
1. Check all connections on suction line and shaft seal with soapy water.
2. Lower suction line into water and re-prime. If receding water level
in well exceeds 25' (7.6M), a deep well pump is needed.
Clean impeller.
Replace check valve or foot valve.
Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Raise foot valve and/or strainer above bottom of water source.
Clean foot valve and strainer.
A deep well jet will be needed if your well is more than 25' (7.6M)
depth to water.
Replace with plastic pipe where possible, otherwise with new steel pipe.
Re-pipe using size of suction and discharge ports on pump.
Add additional well points.
STOP PUMP, tighten clamp nut 1-2 turns. Alternately tighten and tap on
clamp with mallet to seat O-Ring. Do not overtighten.
1-800-468-7867 / 1-800-546-7867
3420P – 2 HP
5' (1.5)
10' (3)
15' (4.6)
69 (261)
64 (242)
65 (246)
65 (246)
62 (235)
60 (227)
59 (223)
56 (212)
54 (204)
52 (197)
50 (189)
48 (181)
47 (178)
45 (170)
42 (159)
42 (159)
38 (144)
35 (132)
34 (129)
30 (113)
27 (102)
25 (95)
18 (68)
13 (49)
14 (53)
7 (26)
9
20' (6.1)
62 (235)
57 (215)
52 (197)
46 (174)
40 (151)
32 (121)
23 (87)
10 (38)

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

3415p3420p

Table des Matières