Programming The Cycles; Type Of Data; Cycle Phase Parameters; Header - Georges Renault DEVICE NET Manuel Opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6 - Programming the Cycles

The function to have access to the data of a phase is available in the TWINCVI/MODCVI.
WARNING: it is not available in MULTICVI's or in MULTICVIC's.
This function allows the user to modify, via the field bus link, the parameters of a phase already programmed. However, it
allows you to access the data such as rotation speed, direction of rotation and power.
Through this functionality, you can neither modify the type of a phase, nor add a phase or delete a phase. The cycles shall
therefore be programmed beforehand, using either the keyboard of the TWINCVI, or the CVIPC2000 software on the PC.

6.1 - Type of data

Acyclic request
Mapping
Address
Instance
0X0600
0X70
0X0650
0X38

6.2 - Cycle Phase Parameters

@ Byte
0X600
Reserved: structure identifier
0X602
Station no.
0X603
Cycle no. (from 1 to 250)
0X606
Phase no.
0X608
Spindle no.
0x60A
Type of phase
0x60C
Phase data
6.2.1 -

Header

To access the data of a phase, it is necessary to know:
The station number:
'1' or '2' in an asynchronous configuration of the CVI, 1 in a synchronous configuration.
The cycle number:
from "001" to "250"
The phase number:
from "01" to "20"
The spindle number:
"01" in an asynchronous configuration of the CVI
" 01" , "02" or "**" for the 2 spindles, in a synchronous configuration
Operator's Manual
DEVICE NET
Class 100
Attribute
0X00
Cycle phase parameters
0X00
Control word
Description
Description
Access
Size
W/R
2
0x0001
W/R
1
"X "
W/R
3
"XXX"
W/R
2
"XX"
W/R
2
W/R
2
"XX"
W/R
68
"XX ............ XX"
Total =
80
6159932680-01
English
13/28
Size
Access
Value
bytes
W/R
80
W/R
2
Value
Type
Word
ASCII
ASCII
ASCII
ASCII
ASCII
Structure

Publicité