3.1 - 24V Inputs/Outputs
This area represents the 24 volt Inputs/Outputs of the tightening controller: they are available in read-only mode.
A station includes 14 inputs of 24 volts which are in read only mode.
Bit
Input Description
16
-
15
-
14
-
13
External stop
12
Synchro In
11
Spindle validation
10
Error acknowledge
9
Reset
8
ES
7
Report request
6
Rotation direction
5
Cycle start
4
Cycle 16
3
Cycle 8
2
Cycle 4
1
Cycle 2
0
Cycle 1

3.2 - Network Inputs/Outputs

The following functions: "start cycle", "rotation direction", "report requested", "emergency stop", "Reset" and "error
acknowledge" are available via DEVICE NET and they have the same functions as the 24V inputs.

3.3 - Input mask

The masks are used to inhibit or validate the functions of the maskable inputs.
The use of masks is useful only with a tightening controller without ISaGRAF application.
A tightening controller with an ISaGRAF application will be able to re-define its network inputs/outputs.
Example:
To authorize the "Start cycle" function via field bus network and inhibit the function via the 24V input, you must set the input
mask to 0x0020 (bit no. 5 positioned).
When an input can be accessed both via network and via 24V input, then an "OR" function is performed between the network
input and the 24V input.
Operator's Manual
DEVICE NET
Output description
-
-
Synchro out
Reset / Save
Reset / No save
-
-
Ready
Cycle in progress
N cycles OK
Reject report
Accept report
Cycle 16 acknowledge
Cycle 8 acknowledge
Cycle 4 acknowledge
Cycle 2 acknowledge
Cycle 1 acknowledge