13. ALARMS

PELLET WORKING
In case of an anomaly during the operation in pellet mode, the electronics of
the stove intervenes and highlights the irregularities that have happened in
the different working phases, depending on the type of fault.
Every alarm situation makes the stove to be automatically blocked. By
pressing button P2 (for 3 seconds) we unblock the stove, for that, on display
we will read "stop", other way is not possible the unblocking. Once the stove
has reached the appropriate cooling temperature, the user can restart it up.
The following table shows the list of alarm codes as well as a description:
ALARM
Er01
Intervention of the safety thermostat, even when the stove is turned off
Er02
Intervention of the safety air pressure switch, only when the smoke fan is working.
Er03
Switching off of the stove due to smoke temperature decrease Possible lack of fuel or blockage of it.
Er05
Switching off of the stove due to overheating of the smoke temperature
Er07
Error Encoder: the encoder of the smoke extractor does not receive signal
Er08
Error Encoder: the adjustment of the smoke extractor speed is not possible
Er11
Values DATE/TIME are not exact after a long power failure
Er12
Ignition of the stove unsuccessful
Er15
Power dip
Er17
The hot air tangential fan does not regulate
Er29
Automatic system that controls the pellet / wood working is blocked.
Er39
Flow sensor broken
Er41
The primary air flow is not enough during the check-up of the stove
Er42
The primary air flow is high
Besides the failure codes, the stove can show the following messages that do not block its operation:
MESSAGE
Prob
Anomaly on the probes control in check-up.
Service
This message means that the operating hours have been reached (1200). It is necessary to call the technical assistance
service.
Block Ignition
This message appears when the system has not been turned off manually during the Ignition phase (after the preload): the
system will turn off when it works at full capacity.
Link Error
Fail of communication between the card and the keyboard (display)
Stand-by
Automatic system that controls the pellet / wood working is into operation.
Cleaning on
Doing a periodic cleaning. Only shown in pellet mode.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
11:30
30º
20º
Er 12
DESCRIPTION
DESCRIPTION
41
CAROL-MIXTA