9. Connection of a photovoltaic station.

Always switch-off power before any operation.
To access the wiring board read the instructions to remove the front cover.
When associated with a photovoltaic system you can store the
excess energy produced in the water heater as hot water. Once
the photovaltaic panels produce enough energy, the inverter
sends a signal to the water heater which switchs into a special
mode ( PV ) activating the heat pump. If the inverter signal stops,
the water heater switches automatically back to the previous
operating mode.
In this PV mode the set temperature is changed to 62 °C (no
modification possible) and on the display appears
The Wire from the photovoltaic installations has to be connected
to a specific connector with screw (delivered in the bag of
accessories). The connector must be inserted into the marker I1
of the controller. It is necessary to drill the bottom plug to pass
the PV cable; a mark indicates the drilling point.
Photovoltaic connection (example) :
AC junction box
Installation
16A
Operation
Maintenance
.
Inverter
MP POWER
Signal 230V~ - 50Hz
3x 1,5mm²
42
Warranty
Photovoltaic
connection
contact 230V ~
PV panels
I1
2A