Electric Connection - Atlantic CALYPSO VM Notice D'utilisation Et D'installation

Chauffe-eau thermodynamique mural
Masquer les pouces Voir aussi pour CALYPSO VM:
Table des Matières

Publicité

Overview
A poor duct installation (duct compressed, length or number of bends too high...) can reduce the
performance. Thus the use of flexible ducts is not recommended.
Number of bends 90°
0
1
2
In case of installation without ducts, it is possible to change the
position of the grids in order to guide the air flow. In order to do
this, it is necessary to unscrew the grids and to re-screw it on one of
the two allowed positions. It is forbidden to place both grids
towards each other.

8. Electric connection

Refer to the electric connections diagram below and on last page.
The water heater must not be switched on before complete filling with water.
The water heater must be connected to electricity supply permanently.
The water heater has to be connected on single phase 230 V alternative current. Connect the water heater
with a cable with rigid conductors with section of 1,5 mm². The installation is composed of :
• A 16A omni-polar circuit breaker with contacts opening at minimum 3mm,
• A 30mA differential circuit breaker.
If the power cable is damaged, the manufacturer, the after-sales service or similarly qualified people must
replace it, to avoid danger.
Never supply power directly to the heating element.
The security thermostat fitted to the auxiliary electric heating element must not be repaired in other places
as our factory. Failure to respect this clause invalidates the warranty.
The device must be installed in accordance with the national electrical installation rules.
Electric connection diagram
Connection to earth is mandatory.
Installation
Operation
Total duct length with air intake and exit (ATL catalogue)
ALUMINIUM SEMI RIGID
10m
8m
6m
16A
Maintenance
3x 1,5mm²
41
Warranty
PEHD;;;;;;;;;;;;;;
21m
17m
13m

Publicité

Table des Matières
loading

Table des Matières