Installation; Product Installation; Prohibited Configurations - Atlantic CALYPSO VM Notice D'utilisation Et D'installation

Chauffe-eau thermodynamique mural
Masquer les pouces Voir aussi pour CALYPSO VM:
Table des Matières

Publicité

Overview

1. Product installation

• Place the water heater in a room protected from frost
• Place it as close as possible to important points of use
• Make sure that the support element is sufficient to receive the weight of the water heater full of water.
It is mandatory to install a retention basin below the water heater if installed above a living area.
A drain connected to the sewer is required.
If the wall is load-bearing (concrete, stone,
brick):
Cut out the printed template on the cardboard
and use it to make the markings. Proceed to the
bolting of bolts Ø 10mm, or to pierce to receive
dowels of type MOLLY Ø 10mm. The wall must
hold a minimum load of 300 kg.

2. Prohibited configurations

• Water heater extracting air from heated room or air with solvents or explosive materials.
• Connection to a heat recovery ventilation unit to the ducts to the attic.
• Duct on outside air and air exit indoor.
• Connection to an underground air duct.
• Water heater installed in a room together with a boiler connected to a chimney with natural draft and 1
duct to outside.
• Direct air connection to a cloth drying machine.
• Installation in dusty rooms.
• Direct air connection to cooking hoods with polluted and fatty air.

Installation

Operation
Installation
Maintenance
If the wall is not load-bearing :
It is mandatory to install the water heater on a
support (optional quadripod). Place the water
heater on the bracket to mark the fixing points.
Make the holes and then reinstall the water
heater in its place. The anti-tilting fixing by the
upper bracket is obligatory (fixing Ø 10mm
minimum adapted to the wall).