3. Settings of the installation.

• Language
Setting possible in French, English, Dutch, Spanish, Portuguese, German, Italian and Polish.
• Date and time
Set the day and confirm. Proceed in the same way for the month, the year, the hour and the minutes.
• Duct (aeraulics operation)
This parameter defines the type of aeraulics connection:
Interior/Interior
Exterior/Exterior
Interior/Exterior
• Heating times
This parameter defines the allowed working hours for the operation of the heat pump and the electric backup
depending on the need of DHW :
H.P. 24h/ ELEC 24h
H.P. 24h / ELEC Prog
H.P. Prog / ELEC Prog
• Anti-Legionella
Allows to activate the function of water disinfection several times per month.
The water temperature reaches 62°C one to four times per month depending on the setting.
• PV system (Photovoltaic)/Smart-grid
This parameter activates the pairing of the water heater with a photovoltaic installation. This operating mode
allows the forced start of the heat pump when the photovoltaic inverter sends a signal to the water heater.
The regulation switches automatically to the previous operating mode 30mn after the loss of the photovoltaic
signal.
During the signal reception the set temperature is automatically raised to 62°C (can not be changed).

4. Advanced settings.

Advanced settings are available in MODE INSTALLER.
Press and hold the button MENU and UP ARROW during 5 seconds.
Access to parameters :
• Lock
Activate the restriction of the settings.
• Emergency mode
When activated the water heater operates only on the electric backup heater.
• Electric backup
Allows to activate or not the use of the electric backup. If not activated, the water heater will never use the
electric backup; in case of low air temperature a lack of hot water is possible.
• Connectivity
The Water Heater can be paired with devices using
Installation
Air intake and exit are not connected to air ducts (ambient air)
Air intake and exit are connected to air ducts (fully ducted)
Air exit is connected to an air duct (semi ducted)
Start of the machine any time of the day,
Start of the heat pump any time of the day, start of the electric backup only during
the programmed period.
Start of the machine during the programmed period only.
Operation
Maintenance
Settings
and remotely controlled.