3. Trouble shooting.

If there is a problem, lack of heating or release of fumes from the water outlet, cut the power supply and
notify your installer.
Repairs have to be done exclusively by a qualified installer.
3.1. Error codes.
The alarm can be paused or reset by pressing OK.
Displayed Code
Water temperature
W.03
probe defect or out
of measuring range
No water in the tank
W.07
or ACI connection
Water temperature
W.09
too hot (T>80°C)
W.12
temperature too
W.15
Date / Hour not set HP stooped if PROG Set the date and hour.
Electrical supply in
W.19
Air intake probe
W.21
defect or out of
measuring range
Evaporator top
probe defect or out
W.22
of measurement
range (-20 to 110)
Pressure switch open
W.25
or compressor
thermal safety
Installation
Reason
Reading of water
temperature
impossible : no
heating up.
No heating up
open
Risk to trigger the
mechanical security
thermostat : no
heating up
Cold water
HP stopped.
Heating with electric
cold(T<5°C)
No heating up
Off peak
HP stopped.
Heating with electric
HP stopped.
Heating with electric
HP stopped.
Heating with electric
Operation
Maintenance
Result
Check the connection (A1) of the probe
(immersion sleeve).
If required replace the probe.
Fill the tank with water.
Check the connection (AC) of the cables, the
water conductivity.
Check the real temperature at a tap (T>80°C).
Check the connection (A1) and the position of
the temperature probe (immersion sleeve).
Check that the electrical backup is not
working permanently. Reset the mechanical
security device if necessary.
Resetting automatically at T>10°C. Control the
situation of the installation room (frost-free).
backup.
Check the electrical supply of the product.
Electrical supply must be permanent.
Check the connections (A2) and the position
of the air intake probe. If necessary replace
backup.
the probe cable harness.
Check the connections (A2) and the correct
contact of the probe to the tube.
Check the operation of the ventilator and that
backup.
it turns easily without any stop.
Check the compressor connections (R1),
pressure switch, starting capacitor (10mF) and
the hot gas valve (T2). Control the resistance
backup.
of compressor windings.
47