HYDRAULIC CONNECTION

A new safety device which conforms to current standards (EN 1487 in
Europe), pressure 0.7 MPa (7 bar) and size 3/4" (20/27) in diameter
must be fitted. The safety valve must be protected from frost.
A pressure reducer (not supplied) is required if the supply pressure is
greater than 0.5 MPa (5 bar) and will be installed on the main supply
pipe.
Connect the safety unit to a discharge pipe, kept in the open air, in a
frost-free environment, continuously sloping downwards to drain off
the heat-expanded water or to allow for drainage of the water
heater.
No components (stop valve, pressure reducer, etc.) must be
positioned between the safety unit and the water heater cold water
branch connection.
For products with a coil: The working pressure of the heat exchanger
circuit must not exceed 0.3 MPa (3 bar), its temperature must not
exceed 100 °C. Do not connect the hot water branch connection
directly to the copper pipes. It must be equipped with a dielectric
union (supplied with the appliance).
In the event of corrosion to the threads of hot water branch
connections not equipped with this protection, our warranty is
invalid.

ELECTRICAL CONNECTION

Be sure to turn off the power before removing the cover, to prevent
any risk of injury or electric shock.
Upstream of the appliance, the electrical installation must have an
all-pole cut-out device (30 mA residual current device) compliant
with the local installation rules in force.
Earthing is mandatory. A special terminal marked
is provided for
this purpose.
In France, it is strictly prohibited to connect a product equipped with
a cable with a plug.
36