geo-FENNEL FL 510HV-G TRACKING M Mode D'emploi page 40

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
SLOPE SETTING
Press this button
The curser is below the sign. Change the sign with the buttons
Press the button
Set the slope values with these buttons
next digit.
Press the button
The slope setting of the Y axis is the same as above. After 8 sec. without entry the instrument will
automatically store the values set. For confirmation the instrument will beep. Then, the TILT mode
preparation will start (3 status).
The percental grade value setting - if registered manually or by tracking - will be retained after powering
off the laser. After powering off and on again the laser the self-levelling procedure starts and the grade
values set before will be retained for both X and Y axis.
The last percental grade value set can be displayed as follows:
·
Keep button
·
Change of the last angle value setting: by manual setting or by tracking (blue button).
·
0-SET of the grade value setting: by pressing both arrow buttons simultaneously.
Important:
Angle values will only be saved by manual registration or in normal tracking mode (blue button)!
In monitoring mode (white button M) no values will be saved.
40
for 2 sec. to enter into the slope mode. The X symbol and „+" will flash.
short to go to the next digit.
again long to select the slope setting of the Y axis.
pressed and then press the arrow buttons
. Press the button
(X axis) or
.
again to select the
(Y- axis).

Publicité

Table des Matières
loading

Table des Matières