Télécharger Imprimer la page

livin flame Skomo Mode D'emploi Et D'installation page 63

Publicité

Les langues disponibles

Les langues disponibles

The stove is clogged
early in the brazier with
burning irregular, door
glass gets dirty, the flame
is long, reddish and weak
Smell of smoke in the
environment. Turning off
the stove.
In the automatic position
the stove always runs at
full power
The
engine
smoke
extraction does not work
1. Flue with presence of stretches too
long or clogged
2. Too pellet
3. Excessive pellet or ash deposits in
the brazier
4. The brazier is not found in its slot
5. Wind contrary to the exhaust flow
6. Insufficient combustion air
7. You changed the type of pellets
used
8. Smoke extractor motor broken
9. Door closed incorrectly
1. Poor combustion
2. Malfunction of fan fumes
3. Installation of the flue performed
incorrectly
4. Clogged chimney
1. Room thermostat set to maximum
2. Significant temperature sensor
failure
3. Control panel defective or broken
1. The stove has no voltage
2. The motor is broken
3. The board is defective
4. The control panel has failed
1. Perform periodic cleaning. See paragraph stove
installation in the user manual. Check chimney cleaning
2. Decrease in the parameters the charge level of the pellets
3. Clean the brazier after waiting for the total shutdown
of the stove. If you repeat contact your Authorized
Service Center
4. Check that the hole in the brazier matches the glow
plug
5. Check the chimney cap windproof and / or possibly
install it
6. Check the correct position of the brazier, its cleanliness
and check that the air intake in both free environment,
verify the status of the door seal, increase the level in the
parameter relative to the speed of the fan exhaust fumes.
Contact your Authorized Service Center
7. Check the quality of the pellets. Contact your
Authorized Service Center
8. Increase the level in the parameters relating to the
speed of the fan exhaust fumes. Check and eventually
replace motor
9. Check that the glass is sealed and the seal guarantees
tightness
1. Contact your Authorized Service Center
2. Contact your Authorized Service Center
3. Contact your Authorized Service Center
4. Contact your Authorized Service Center
1. Reset the thermostat temperature
2. Check the operation of the sensor and replace if
necessary
3. Check the control panel and replace if necessary
1. Check the supply voltage and the protection fuse.
2. Check the motor and capacitor and replace if necessary.
3. Replace the circuit board.
4. Replace the control panel.
29

Publicité

loading