Without "Safe Standstill" Function - Lenze 9300 vector Instructions De Montage

Masquer les pouces Voir aussi pour 9300 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Show/Hide Bookmarks
4.7.2

Without "safe standstill" function

If you do not use the "safe standstill" function, the safety relay K
a current, so that the drivers of the power output stage are supplied with voltage.
Internal voltage supply
+5 V
Fig.9-14
ƒ For supplying the digital inputs (X5/E1 ... X5/E5, X5/ST1) a freely assignable digital
Supply via external voltage source
+5 V
Fig.9-15
EDKVF9383 DE/EN/FR 1.0
+
K
SR
X11 K31 K32 33 34
X5 28 E1 E2 E3 E4
S1
Wiring of inputs and outputs without "safe standstill" function at internal voltage supply
S1
Enable controller
The min. wiring requirements for operation
output (e. g. X5/A1) must be firmly applied to HIGH level.
+
K
SR
X11 K31 K32 33 34
X5 28 E1 E2 E3 E4
S1
Wiring of inputs and outputs without "safe standstill" function at external voltage supply
S1
Enable controller
The min. wiring requirements for operation
Electrical installation
Wiring of digital inputs and outputs
Without "safe standstill" function
GND2
E5
39
A1
A2 A3 A4 ST1ST2 59
GND2
E5
39
A1
A2 A3 A4 ST1ST2 59
+
DC 24 V
(+18 V ... +30 V)
must permanently carry
SR
+24V
9300vec066
+24V
9300vec053
4
75

Publicité

Table des Matières
loading

Table des Matières