Show/Hide Bookmarks
4
Electrical installation
Wiring of analog inputs and outputs
Terminal assignment
4.8.1
Terminal assignment
X6/1
X6/2
X6/3
X6/4
X6/62
X6/63
X6/7
78
Signal
Function
type
Bold print = Lenze setting
Analog
Differential input of
input 1
master voltage
Main setpoint
Differential input of
master current
Analog
Differential input of
input 2
master voltage
Not active
Analog
Monitor 1
output 1
Actual speed value
Analog
Monitor 2
output 2
Actual motor current value
–
GND1, reference potential for analog
signals
Level
-10 V ... +10 V
6
5
4
3
2
1
Jumper X3
-20 mA ... +20
6
5
mA
4
3
2
1
Jumper X3
Jumper X3 has
-10 V ... +10 V
no effect
-10 V ... +10 V
max. 2 mA
-10 V ... +10 V
max. 2 mA
–
Technical data
Resolution:
5 mV (11 bits + sign)
Resolution:
20
A (10 bits + sign)
µ
Resolution:
5 mV (11 bits + sign)
Resolution:
20 mV (9 bits + sign)
Resolution:
20 mV (9 bits + sign)
–
EDKVF9383 DE/EN/FR 1.0