5.5 MOTOR FAN REPLACEMENT
If the equipment is provided with fan, and you need to replace it, removing the power supply, checking the data plate
of the motor fan and replace it with one of with same power, voltage and frequency.
These operations must be done by a technician!
5.6 COMPRESSOR / REFRIGERANT GAS REPLACEMENT
In the case of damage and / or replacement of the compressor, recover the refrigerant gas and the oil avoiding dispersion in the environment.
The repalcement must be done by a technician!
5.7 UNIT FITTED WITH ELECTRIC DEFROSTING
Before maintenance is necessary to turn off or unplug the refrigerator equipment.
In the equipments with electric defrosting system pay attention to the electrical heating element that
can still be hot. Then, wait for it to cool and then start the maintenance operations.
Attention! During cleaning operations, it is high recommended to use working gloves.
5.8 GARBAGE DISPOSAL
Plastic, gaskets, sheet metal, polyurethane components, panel controls and electric material in general
must be saved and/or dumped in public dumps and/or garbage authorized centre. Be sure not to disper-
se. Save the refrigerating gas and oil in special tanks, do not dispose of them in the sewage system but
dump them in according to your local laws.
5.9 REQUESTING SPARE PARTS
After verifying the problem with a specialized technician, When requesting spare parts, after please say clearly :
Model of the item
Serial number of the item
Motivation of the request of support
Quantity of the spare part
Possibly, enclose also a picture of the part to be ordered.
General product information:
code HSDjkz (identification of single particular code of the family HSD
- Horizontal serve-over displays)
"HSD" TYPE OF PRODUCT
possible options
HSD = Horizontal serve-over display - horizontal refrigerator
"j" size (horizontal length) of EUT
possible options
0060 = length 60 cm
0090 = length 90 cm
0096 = length 96 cm
0100 = length 100 cm
0120 = length 120 cm
0125 = length 125 cm
0136 = length 136 cm
0140 = length 140 cm
0150 = length 150 cm
0180 = length 180 cm
0182 = length 182 cm
0200 = length 200 cm
SALINA - KIBUK | User and Maintenance Manual | EN
ATTENTION
0240 = length 240 cm
0250 = length 250 cm
0262 = length 262 cm
0280 = length 280 cm
0300 = length 300 cm
0350 = length 350 cm
0375 = length 375 cm
0380 = length 380 cm
"k" additional configuration of EUT
possible options
S =
without motor (compresser)
C = with motor (compresser)
N = without motor (compresser) and without other
electric components; appliance
provide only with internai light - expositor unit
"z" additional configuration of EUT
possible options
W = with electrical defrost (resistance)
X = with hot gas defrost (additionat by-pass valve)
Y = Stopping defrost (compresser turn off)