2.6.1.1. Numbering machine range
Step width
Repeats
Downwards
Leading zeroes
2.6.1.2. Number circle
The number circle defines the value range in which a numberer counter.
When the maximum or minimum value is reached (when the numberer counts up or down),
the count is continued on the respective other end of the scale.
Minimum
Maximum
Actual value
2.6.1.3. Figure style
Selection option between "Figure style1" and "Figure style 2".
"Figure style 1" and "Figure style 2" can be configured in the tab "Figure style" in the menu
"Settings" (see "Menu commands", page 59).
68
Indicates the interval at which the numberer counts on (e.g. 1,4,7... in
steps of 3).
Indicates the number of repetitions of an imprint. If, e.g., the value 3
is set, the numberer remains on the same number for three imprints
before it counts on.
The repeat factor can be set from 0 to 99.
The numberer switches on at the value 0.
The numberer can count up (e.g. 10, 11, 12 ...) or down
(e.g. 10, 9, 8, ...).
Leading zeroes can be suppressed or printed (e.g. 5 or 00000005).
The number of printed digits depends on the maximums set under
"Number circle".
This value marks the lower limit of the number circle.
This value marks the upper limit of the number circle.
The current counter reading can be set within the defined value range.