Technical Data; What To Do If - Becker Centronic UnitControl UC52 Notice De Montage Et D'utilisation

Masquer les pouces Voir aussi pour Centronic UnitControl UC52:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Rated voltage
Switching current
Power consumption
Degree of protection
Class of protection
(dependent on correct assembly)
Permissible ambient temperature
Type of mounting
Problem
Drive is not functioning.
Drive is running in the
wrong direction.
The control unit does
not perform the external
commands.

Technical data

230 V AC / 50 Hz
5 A / 250 V AC at cos
2 VA
IP 20
II
0 to +55 °C
Flush mounted Ø 58 mm, wall moun-
ted/surface mounted in appropriate
surface mounted housing

What to do if...?

Cause
Incorrect connection.
Incorrect connection.
The slide switch is set to
Manual mode.
Alarm signal pending.
=1
Remedy
Check connection.
Swap over wire
wire
on the power
supply unit.
Set the slide switch to
Automatic mode.
Wait for the alarm signal
to disappear or dismiss
it.
and
27 - en