Travelling to tilt position (blind)
When using the blind function, the blind moves in touch mode in order to en-
able precise positioning of the slats. If a travel button is pressed for more than
1 second, the blind moves in maintained operation.
After the programmed intermediate position is reached, the slats are automat-
ically tilted (provided the tilt position has been programmed).
Travelling to intermediate position
Only travel the shading solution to the intermediate position or programme it
from the upper limit position.
To do so, press the DOWN button briefly twice in succession. The shading
solution moves to the saved intermediate position.
Travelling to ventilation position
Only travel the shading solution to the ventilation position or programme it
from the upper limit position.
To do so, press the UP button briefly twice in succession. The shading solu-
tion moves to the saved ventilation position.
Setting the coding switch:
1.
Lower position
2.
Upper position
3.
Lower position
Programming intermediate position
Prerequisite: The roller shutter/blind is in the upper limit position.
1.
Press and hold the intermediate position programming button
2.
Also press the DOWN button until you reach the desired intermediate po-
sition. Adjustments can be made using the UP button or DOWN button.
3.
Release the intermediate position programming button
diate position is now saved.
The indicator lamp flashes briefly three times.

Factory default settings

Programming

Alarm signal function on
Drive controller
Roller shutter/awning mode
.
. The interme-