Setting Up And Activating Power Supply Mode - tbs electronics Omnicharge2 OC2 12-40 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Setting up battery banks 2 and 3 works exactly the same as in the described example in this
chapter. Just make sure that battery bank 2 or 3 is selected in the top (start-) level of the
setup menu, which is indicated by respectively B2 or B3 on the left of the battery icon in the
display (see next image).
Configure battery bank 2
4.2

Setting up and activating Power Supply mode

In Power Supply mode, the charger only delivers a constant voltage and all charge steps are
disabled. The voltage and maximum output current levels are selectable. Please see the next
table for the available voltage and current options:
Model
Voltage options
2
OC
12-40
10.5V/11.5V/12.5V/13.5V/14.5V
2
OC
12-60
10.5V/11.5V/12.5V/13.5V/14.5V
2
OC
24-20
21.0V/23.0V/25.0V/27.0V/29.0V
2
OC
24-30
21.0V/23.0V/25.0V/27.0V/29.0V
To activate the Power supply mode we need to enter the setup mode by pressing the MENU
button for 3 seconds. In the setup mode, press the NEXT (>) button 3 times to reach the
Power Supply (PSU) section as indicated below:
Configure battery bank 1
From this screen press SET to enter the voltage setup screen as indicated below:
Configure battery bank 3
Max. current options
40A/20A/10A/5A
60A/40A/20A/5A
20A/15A/10A/5A
30A/20A/10A/5A
Configure Power Supply
NEXT x3
22
Defaults
13.5V/40A
13.5V/60A
27.0V/20A
27.0V/30A
mode