Configuring The Battery Charger - tbs electronics Omnicharge2 OC2 12-40 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4. CONFIGURING THE BATTERY CHARGER

The factory default settings inside the Omnicharge
to fit most standard situations. Please see the next table showing these default values:
Model
Parameter
Battery type
Absorption voltage
Maximum charge current
End of charge current
2
OC
12-40
Mode (float=3, no float=2)
Float voltage (if Mode=3)
Battery temperature
Charge restart voltage
Battery type
Absorption voltage
Maximum charge current
End of charge current
2
OC
12-60
Mode (float=3, no float=2)
Float voltage (if Mode=3)
Battery temperature
Charge restart voltage
Battery type
Absorption voltage
Maximum charge current
End of charge current
2
OC
24-20
Mode (float=3, no float=2)
Float voltage (if Mode=3)
Battery temperature
Charge restart voltage
Battery type
Absorption voltage
Maximum charge current
End of charge current
2
OC
24-30
Mode (float=3, no float=2)
Float voltage (if Mode=3)
Battery temperature
Charge restart voltage
As you can see the factory default battery type is set to Flooded, as it's absorption and float
voltage values are quite standard and may even fit other lead based battery types. However,
when you wish to optimally adapt the charger to your batteries, there are also standard
charge programs available for GEL, AGM and Lithium batteries. See the table below with the
standard voltage parameter settings for the battery types:
2
battery chargers were carefully adjusted
Value (valid for all 3 outputs)
Flooded
14.4V
40A
4A
3
13.5V
Normal
12.5V
Flooded
14.4V
60A
6A
3
13.5V
Normal
12.5V
Flooded
28.8V
20A
2A
3
27.0V
Normal
25.0V
Flooded
28.8V
30A
3A
3
27.0V
Normal
25.0V
16

Publicité

Table des Matières
loading

Table des Matières