Temperature
setting
T.LO (Low)
T.NO (Normal)
T.HI (High)
There is no charge voltage adjustment for Lithium battery types.
When the BTS is not being used, never set the battery temperature lower than the actual
temperature. This may overcharge and damage the battery.
3.4

Forced restart of the charging process

When it is desired to restart the charging process manually, without
having to recycle AC power by disconnecting the AC plug, please press
the MENU and SET buttons simultaneously for 3 seconds. After this, the
charger will automatically restart the charging process by entering the
Bulk charge stage.
Recommended for
battery temperature
< 5°C
> 5°C and < 30°C
> 30°C
WARNING
Battery type
Gel, Flooded
AGM
Gel, Flooded
AGM
Gel, Flooded
AGM
15
Voltage adjustment
from 25°C setting
12V
24V
+0.675V
+1.350V
+0.525V
+1.050V
0V
0V
0V
0V
-0.27V
-0.54V
-0.21V
-0.42V