Dimensions

9.

Assembly Instructions

Warning!
Secure the electric connection with an earth leakage circuit breaker (RCD).
Failure to observe can mean risk of death or material damage, e.g. from electric
shock or fire.
Caution!
Do not install the solenoid valve within the urinal.
Failure to observe can result in material damage.
The system cable (not included in the scope of supply) for connecting the power
supply to the fittings must be installed in a conduit (to be supplied by customer) and
looped through.
Where improper installations cause mutual influencing between neighbouring
urinals, this can be compensated by changing the sensitivity of the system and by
additionally engaging the immunity mode (see
9.1
Install the solenoid valve (d) within a radius of 0.3 m from the siphon.
9.2
Connect the solenoid valve (d) with the water supply and the urinal.
9.3
Check the function of the sensor (see
9.4
Use the pre-mounted re-closable fastener hook to fasten the sensor (a) to the siphon
(b).
9.5
Connect the control unit (c) to the solenoid valve (d) and the sensor (a).
9.6
Connect the power supply (e) to the mains (f, 230 V AC).
9.7
Mount the urinal.
The customer must provide the piping between urinal drain and siphon.
9.8
Connect the urinal drain with siphon (b).
9.9
Use an Allen key to open/close the water volume regulator.
a: Closed
b: Open
9.10 Pour at least 2l water into the urinal.
• The first flush is triggered after 90s.
• The system is ready.