5.2

Technical data

Max. volume flow
Max. delivery head
Speed
Mains voltage
Frequency
Rated current
Energy Efficiency Index (EEI)
Insulation class
Protection class
Power consumption P
Nominal diameters
Pump weight
Permitted ambient temperature
Fluid temperatures at max. ambient
temperature +40 °C
Fluid temperatures at max. ambient
temperature +25 °C
Temperature class
Max. rel. humidity
Maximum permissible operating
pressure
Approved fluids
Emission sound-pressure level
Residual current DI
Electromagnetic compatibility
1)
Reference value for the most efficient circulation pumps: EEI ≤ 0.20
2)
See the following warning
Installation and operating instructions Wilo-Yonos ECO BMS
depends on the pump type, see catalogue
depends on the pump type, see catalogue
depends on the pump type, see catalogue
1~230 V ±10% in acc. with DIN IEC 60038
50/60 Hz
See rating plate
1)
See rating plate
See rating plate
See rating plate
See rating plate
1
see type key
depends on the pump type, see catalogue
-10 °C to +65° C
-10 °C to +95 °C
-10 °C to +110 °C
TF110
≤ 95%
PN 10
Heating water in accordance with VDI 2035 Part 1 and Part 2
Water/glycol mixtures, max. mixing ratio 1:1 (for mixtures
with glycol the conveying data of the pump should be cor -
rected to those for the higher viscosity, depending on the
percentage mixing ratio)
Only use brand-name goods with corrosion protection inhibi -
tors; comply with the manufacturer's specifications and safety
data sheets.
The pump manufacturer's approval must be obtained for
the use of other fluids.
Ethylene/propylene glycol with corrosion inhibitors.
No oxygen binding agents, no chemical sealants (ensure
enclosed system from corrosion perspective according to
VDI 2035; rework leaky points).
Commercially available anti-corrosion agents
rosive anodic inhibitors (e.g. underdosing due to consump -
tion).
Commercially available combination products
ganic or polymer film formers.
Commercially available cooling brines
< 32 dB(A)
≤ 3.5 mA (also see chapter 7.2)
Emitted interference in acc. with:
EN 61800-3:2004+A1:2012 / Residential (C1)
Interference resistance in acc. with:
EN 61800-3:2004+A1:2012 / Industrial (C2)
2)
without cor -
2)
without inor -
2)
English
25