Operation / Display; Slope Y Axis (Figure 1) - THEIS VISION 2N AUTOSLOPE ALIGN Instructions De Service

Masquer les pouces Voir aussi pour VISION 2N AUTOSLOPE ALIGN:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Note:
(1) While searching for the detector, changes may occur in the ro-
tation speed and in the blanking zones.
(2) There must be no obstructions between laser and detector,
otherwise this will impact the search speed and make search-
ing more difficult.
(3) If a second normal detector is to be used during the ALIGN
state, to determine intermediate points, for example, take care
that you do not cover the receiving field of TE 90 ALIGN with
this detector, but remains below or above it. This could result
in an incorrect result.

12.1.2 Operation / display

12.1.2.1 Slope Y axis (Figure 1)

TE 90 ALIGN
Turn on the detector.
Device symbol must al-
ways be displayed.
Set detector at short distance before laser to reference height.
Then move detector to target point M2. M2 must be exactly on the
Y axis (telescopic sight recommended).
Y axis
Press A key briefly.
Start ALIGN in Y axis.
Search complete:
Y or Y alternating and slope
value _._ _ flashing in alterna-
tion.
VISION 2N ALIGN
Turn on the laser.
Laser approaches
end switch and
levels.
Leveling begins.
Laser searches
for detector.
Detector found.
53
0.00%
A
Y
_._ _%
A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vision 2n align

Table des Matières