Technical Data; What To Do If - Becker Centronic SunWindControl SWC510 Notice De Montage Et D'utilisation

Masquer les pouces Voir aussi pour Centronic SunWindControl SWC510:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Nominal voltage
Switched current
System of protection
Permissible ambient temperature
Running time
Radio frequency
Problem
Drive is not functioning.
Blind or shutter moves in
the wrong direction.
The SWC510 does not
execute manual control
commands from a hand-
held transmitter.
Automatic control com-
mands are not carried
out
The system does not
automatically extend
when should the sliding
switch be set to "S"
The system does not
extend in response to a
manual command when
the sliding switch is set
to "H" or "S".
Technical data
What to do if ...?
Cause
Faulty connection.
Faulty connection.
The transmitter has not
been programmed in
the SWC510
1. The transmit-
ter has not been
programmed in the
SWC510
2. The sliding switch of
the hand-held/wall
transmitter is set to
manual mode "H".
1. The sunlight thresh-
old value has not been
reached.
2. The wind thresh-
old value is has been
exceeded.
The wind threshold
value of the transmitter
has been exceeded.
230-240 V AC / 50-60 Hz
5A /230240 V AC for cos ϕ =1
IP 44
-25 to +55 °C
2 min
868.3 MHz
Remedy
Check connection.
Exchange the s and t
wires at the SWC510
Programme transmitter.
1. Programme transmit-
ter.
2. Adjust the sliding
switch of the hand-
held/wall transmitter
to automatic mode
"S".
1. Adjust sunlight
threshold value using
the transmitter.
2. Wait until wind
abates.
Wait until wind abates.
de
en
fr
nl
23