8.3

Performing the pressing operation

EN
1.
2.
3.
4.
• if using a press collar: first detach the adaptor jaw from the press collar, then
• detach the press jaw/press collar from the press fitting (Fig. 7).
CAUTION!
Danger of crushing!
There is a risk that fingers and hands will be crushed.
Therefore:
– Keep body parts and foreign objects away from the press jaws during the pressing
operation.
– Do not hold the jaw levers with your hands during the pressing operation.
Information!
The device will not start if the retaining pin (5) is incorrectly inserted. The green LED
flashes.
Information!
Always comply with the operating instructions for the press tools.
Check whether the nominal width of the press fitting matches the nominal width of the
press jaw/press collar.
Comply with the system manufacturer's instructions when fitting the press jaw/press collar
(Fig. 5)
If using a press collar: Fit the adaptor jaw to the press collar as described in the press
collar manufacturer's instructions.
Information!
Make sure that the press jaw is fully closed when the pressing operation
is complete (Fig. 6)
Information!
Ensure there is no gap between the segments of the press collar when
the pressing operation is complete.
To start the operation, press the start button (1) and keep pressed for at least 2 seconds
until the automatic press cycle.
When the pressing operation has been completed