EUROM PAC 12 Livret D'instructions page 22

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

End of season cleaning
If the device is to be stored for a long period, you must take the
following measures!
 Remove the condensed water. Run the unit for a few hours on fan
function so that the unit is completely dry inside.
Then switch the air conditioning unit off, remove the plug from the
socket and:
 clean the filters and reposition them or replace with new ones;
 unscrew the waste pipe from the device in order to prevent
damage;
 pack the air conditioning unit in its original packaging or in a plastic
bag and place in a dry place for storage. Place a heavy object on
the unit.
TROUBLE SHOOTING
The unit does not start if I press the ON/OFF button
 Is the plug in the socket?
 Is the earth leakage circuit breaker engaged? No power?
 Is the water tank full? Empty it.
 The room temperature is lower than the set temperature; amend
the set temperature.
The unit doesn't seem to be very effective
 Measure the outlet temperature; this must be approx. 10° cooler
than room temperature.
 Is there direct sunlight? Shut the curtains.
 Are windows or doors open? Shut them.
 Are there too many people in the room? They produce heat!
 Is the space too big?
 Is there an object in the room that is generating (a great deal of)
heat? Switch it off or remove it.
 Is the filter dusty or covered in dirt? Clean it.
 Is the air inlet or outlet (hose) blocked? Make sure there is free air
flow.
The unit is making a noise
 Is the surface underneath the machine sturdy and even?
 The flow of coolant in the unit also produces a little noise. This is
perfectly normal.
The unit switches itself off
 The overheating safeguard may have switched the unit off. See
'Safety'.