Manual cleaning
If the suction power decreases, cleaning
can be started manually by turning the
switch [1-9] to the AC symbol positioned on ei­
ther side of the switch.
We recommend cleaning the main filter com­
pletely if severely clogged:
► Set the suction power adjuster [1-8] to the
maximum setting.
► Cover the end of the nozzle or suction hose
with your hand for 10 seconds.
► Turn the switch [1-9] to the AC symbol.
When the CT-VS closing slide is used (or­
der no.: 497926), the filter can be cleaned
fully without removing the connected elec­
tric power tools.
In intensive applications that generate adherent
dust, it may be necessary to clean the filter ele­
ment mechanically under certain circumstan­
ces (extract). Wear a dust mask!
8.7
Applying the brake
Folding out the brake lever [1-13] prevents the
mobile dust extractor from rolling. To achieve
this, lift the front end of the mobile dust extrac­
tor slightly and push the brake lever down­
wards until it latches into place. Push the lev­
er [1-12] again to release.
9

Working

9.1
Handling
Hose store: after finisching work, you can feed
the suction hose through the recess [4-2] and
place it in the hose store.
SysDoc Systainer attachment system: a
Systainer can be attached to the storeage area
via the four slides ore the T-Loc [4-1] .
4
4-2
4-1
9.2
Extracting dry materials
Hazardous dust
Damage to the respiratory passage
► Use a filter or disposal bag when extracting
hazardous materials!
► Do not use the machine if the volumetric
flow monitoring function is inactive.
Observe the following when extracting dust
generated by operating electric power tools:
If the exhaust air is discharged back into the
room, the air renewal rate L within the room
must be sufficient. The volume of air dis­
charged back into the room must not exceed
50% of the fresh air volume flow (room volume
V
x air renewal rate L
R
vant regional regulations.
Remember: A moist main filter clogs more
quickly when extracting dry materials. There­
fore, dry the main filter before extracting dust
or replace the damp filter with a dry one.
9.3
Extracting fluids
Risk of injury
► Do not evacuate combustible liquids!
The main filter shall only be used for ex­
tracting dry materials.
Before extracting fluids, remove the filter bag
(see chapter 10.1). We recommend using a
special wet filter.
The dust extractor stops automatically when
the maximum level is reached.
Escaping foam and fluids
► Switch off the machine immediately and
empty the dust container.
Hazardous dust
Damage to the respiratory passage
► After extracting wet materials, remove the
wet filter and replace it with the main filter
for dry materials.
4-1
9.4
Special features of the CT 36 E AC- LHS