7.5 Maintenance

Regularly (approx. once a month) check the water supply tube and water drain tube for leaks and
adequate slope.
For water-cooled machines, the cooling water controller should be checked regularly for proper
function, because failure of the cooling water controller to close or close fully will lead to in-
creased water consumption and therefore higher operating costs. The condensation temperature
should be 30°C. With the machine switched off, no water should emerge from the cooling water
drain tube. Built-in machines may have to be removed for this purpose.
During reinstallation, prevent bending or kinking of the drain tube or the cooling water drain tube,
so that the water can drain freely!
The position of the limit switch
must also always be observed be-
cause it can easily move. The fol-
lowing illustration shows how the
two limit switches should be posi-
tioned.
The upper limit switch above -
perpendicular to the floor surface.
The lower limit switch below -
horizontal to the floor surface
IMPORTANT:
Other maintenance work should only be carried out by authorised WESSAMAT service
technician or service staff from authorised specialised dealers!
The frequency of maintenance depends on the place of installation and the water quality (e.g.
water hardness, contaminants etc.). Maintenance schedules therefore have to be determined in-
dividually and can either be agreed jointly or recommended by your specialist dealer