Ice capacity of the ice
cube maker too low
Water spills over the
edge of the tub during
ice cube production
Tub is not filled with wa-
ter
User-manual-CombiLine-W80-W120-W240-0299-2
1. Condenser is soiled
2. Insufficient ventilation
3. Room / ambient tem-
perature is too high
4. Cooling water controller
not working properly
1. Machine is not level
2. Tube has moved down
3. Water level sensor is
soiled
1.
Water
inlet
clogged or soiled
2. Electrical fault in water
inlet valve
3. Water level sensor af-
fected
by
a
'moisture
bridge'
4. Fault in water sensor
electronics
1. Clean condenser
Verflüssiger Reinigen
2. Check specified lateral distances
and ensure optimum air circulation
3. Reduce room/ambient tempera-
ture, if necessary relocate the ma-
chine. Replace air-cooled machine
with water-cooled machine if neces-
sary
4. Check cooling water controller,
setpoint temperature +30°C, read-
just or replace if necessary
1. Align machine
2. Readjust tub
3. Clean / descale water level sen-
sor
valve
1. Clean pre-screen
2. Check input voltage, replace wa-
ter inlet valve if necessary
3. Dry the water level sensor
4. Replace water sensor electronics
Seite 70