Trouble Shooting - HOLZMANN MASCHINEN BS 210TOP Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

15

TROUBLE SHOOTING

BEFORE YOU START WORKING FOR THE ELIMINATION OF DEFECTS, DISCONNECT THE
MACHINE FROM THE POWER SUPPLY.
Trouble
Machine does not start
Saw band does not come to full
speed, no power
Motor gets hot very fast and
has weak performance
Saw band runs in opposite
direction
Machine vibrates
Bad cuts
MANY POTENTIAL SOURCES OF ERROR CAN BE CLEARED BY THE EXPERTLY CONNECTION
TO THE ELECTRICITY GRID.
Should you in necessary repairs not able to properly to perform or you
have not the prescribed training for it always attract a workshop to fix
the problem.
HOLZMANN MASCHINEN GmbH
Possible cause
Machine not connected to
power supply
Fuse of power circuit defect
or not suitable
Cable defect
To long extension cord
Power supply not matching
with motor requirements.
Weak, instable/volatile power
supply
Motor does not receive power
on one or even 2 phases
2 of the 3 leading phases are
switched whether in Plug or
socket
Placed on uneven
underground
Motor or any other parts
loose
too high descent velocity
unsuitable saw band for
cutted material
worn saw band
saw band not tensioned
correctly
saw band guide outbalanced
www.holzmann-maschinen.at
Check all power connections
Change fuse
Change cable
change to suitable extension
cord with sufficient cross-
section, insulation and length
Let check by electrician
Contact electric power
company
Shut off machine
immediately. Let the
connection to supply circuit
be checked by an electrician!
Shut off machine
immediately. Let the
connection to supply circuit
be corrected by an
electrician!
modify
check all screw joints if
tightened
Reduce the descent velocity
Use e.g. for stainless steel HQ
Bi-Metal bands only
replace
tension saw band correctly
readjust saw band guide
NOTICE
TROUBLE SHOOTING
Solution
32
BS 210TOP / BS 275TOP

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bs 275top

Table des Matières