OPERATING INSTRUCTIONS OF
Replace the electric cables and/or the components to
which they are connected if there are signs of wear,
sheath cut, outlet damage or plastic and sheath darkening
around the coupling area. Replace the electric cables
and/or the components to which they are connected
if there are signs of wear, sheath cut, outlet damage
or plastic and sheath darkening around the coupling
area. Never disassemble the protective housings of the
cylinder, battery pack, remote control, control box, and
battery charger.
5.3) Charging test
Charge the battery pack
Check the battery pack power and autonomy
Test the device when fully loaded (175 Kg) and control
the power cut threshold (230 Kg +/- 10 Kg).

5.4) Maintenance book

Every maintenance operation or intervention should
be recorded in the service book attached to these
instructions
VIII - SHIPPING, STORAGE, AND
DISPOSAL
The patient lift should be returned or transported in its
original packaging.
Before storing the patient lift, clean it totally and check
its performance. Store the patient lift in a dry place away
from dust and humidity. The batteries should be totally
charged every 3 months
When commissioning, after storing, charge the battery
pack, and check its performance before using it again.
Storage temperature : ..........................from 0 to + 50°C
..............................................Humidity between 10 and 80%
Service temperature : .......................from + 10 to + 40°C
............................................. Humidity between 30 and 80%
The disposal of defective parts, packaging and battery
pack should be performed by approved waste treatment
centres.
The involved system should not be disposed of with
household waste, but should be sent to an appropriate
waste collection point or to a distributor.
By respecting these instructions, you respect the
environment and participate in protecting the natural
resources and the human health.
Samsoft 175
IX - LIABILITY AND WARANTY
CONDITIONS
Samsoft 175
structure, the cylinder and the control box are concerned,
and in case of normal use according to the instructions
given in this guide. Negligence, handling errors and
accidents are excluded from the warranty. The remote
control is guaranteed for 3 months, and the battery pack
is guaranteed for 6 months.
Any modifi cation or addition of accessories without
drive DeVilbiss Healthcare France's written consent
will de facto exclude the patient lift from the warranty
and from drive DeVilbiss Healthcare France liability. In
particular, using slings that are not marketed by drive
DeVilbiss Healthcare France for this patient lift will not
entail our liability.
The regular checks and inspections mentioned in the
previous paragraph should be performed by a competent
staff and recorded in the maintenance book.
Out of the warranty period, our liability will not be
entailed if you do not respect these controls and
inspections.
Only spare parts and components provided by drive
DeVilbiss Healthcare France can be used to repair the
patient lift.
is warranted for 5 years as far as the