Metric units
Max. cleaning capacity*
Blower motor
Wiring
kW (hp)
rpm
Distributor impeller
Wiring, motor speed control
Motor, kW (hp)
Motor, normal rpm**
Weight w/o extra equipment
Max. recommended pipe length
on blower discharge***
Imperial units
Max. cleaning capacity*
Blower motor (60 Hz)
Wiring
Hp
rpm
Distributor impeller
Wiring, motor speed control
Motor, hp
Motor, normal rpm**
Weight w/out extra equipment
Max. recommended pipe length
on blower discharge***
*) Given cleaning capacities are indicative only. The capacity will vary depending on the material and the
degree of cleaning required.
**) Frequency inverter required.
***) Horizontal pipe, incl. two 90° elbows and one cyclone. Long pipe lengths can reduce cleaning capacity.

Dimensions, mm (inch)

615 (24.2 in)
1032 (40.0 in)
KIA 12
22
KIA 12
KIA 20
300 kg/h
700 kg/h
3 x 400V/50Hz
3 x 400V/50Hz
0.75 (1.0)
2.2 (3.0)
3000
3000
1 x 230V/50Hz
0.18 (0.25)
100-200
49 kg
125 kg
25 metres
15 metres

(type OK160)

(type OK200)
KIA 12
KIA 20
660 lb/h
1540 lb/h
3 x 460V/3 x 575V
3 x 460V/3 x 575V
1.5
3.0
3500
3500
1 x 230V/60 Hz
1
100-200
108 lb
275 lb
80 ft
50 ft
(type OK160)
(type OK200)
853 (33.6 in)
KIA 20
KIA 60
2250 kg/h
3 x 400V/50Hz
7.5 (10.0)
3000
1 x 230V/50Hz
0.55 (0.75)
100-200
260 kg
15 metres
(type FK300)
KIA 60
4950 lb/h
3 x 460V/3 x 575V
10.0
3500
1 x 230V/60 Hz
1.5
100-200
572 lb
50 ft
(type FK300)
ø1076 (42.4 in)