NOTES ON TROUBLESHOOTING

Defect
Motor does not run
Tool loses oil
Tool does not reach
final pressure
Battery does not charge
If the defects cannot be remedied, send the tool to
the REHAU service center or your dealer!
36
Cause
- Tool/Battery contacts dirty
- Tool/Battery contacts damaged
- Battery not correctly locked into the tool
- Battery empty
- Battery faulty
- Tool faulty
- Leak in oil tank or release valve
- Leak in oil tank or release valve
- Air in the hydraulic system
- Tool faulty
- Charger not plugged in correctly
- No power coming to socket
- Charger / Mains cable or plug damaged
- Charger not ready
- Charger/Battery contacts dirty
- Charger/Battery contacts damaged
- Battery not locked correctly into
the charger
Correction
Clean contacts when dry with
non-conducting material
Send tool/battery to REHAU service center
Reinsert battery, pay attention to
locking mechanism!
Charge battery
Send battery to REHAU service center
or independently give it to the recycling system
Send tool to REHAU service center
Do not open the tool and do not remove or
damage the tool seal!
Send tool to REHAU service center
Do not open the tool and do not remove
or damage the tool seal!
Send tool to REHAU service center
Interrupt the expansion process.
Hold reset knob under tension (see page 25/
Item No. 2) and at the same time continuously
actuate the operating switch for about 10
seconds, (see page 25/Item No. 1).
If this does not correct the defect, the tool
must be sent to a REHAU service center.
Send tool to REHAU service center
Remove and then reinsert mains plug
Change socket
Send charger to REHAU service center
Wait for green LED to flash
Clean contacts when dry with
non-conducting material
Send charger/battery to REHAU service center
Reinsert battery, pay attention to locking
mechanism!