Liste des données ModBus
Code
Nom
Fonc.
C143 Logic function select
C144 Terminal [11] ON delay
C145 Terminal [11] OFF
delay
C146 Terminal [12] ON delay R/W Range is 0.0 to 100.0 sec.
C147 Terminal [12] OFF
delay
C148 Output relay ON delay
C149 Output relay OFF delay R/W Range is 0.0 to 100.0 sec.
Nota 1 :
Fonctions de connexions intelligentes du Groupe "C"
R/W
R/W Applies a logic function to
calculate [LOG] output state,
three options:
00 ... [LOG] = A AND B
01 ...[LOG] = A OR B
02 ...[LOG] = A XOR B
R/W Range is 0.0 to 100.0 sec.
R/W Range is 0.0 to 100.0 sec.
R/W Range is 0.0 to 100.0 sec.
R/W Range is 0.0 to 100.0 sec.
Suppose que le courant nominal du variateur est égal à 10000 (pour C041).
Description
hex
1152h 04434
1153h 04435 0 to 1000 0.1 sec
1154h 04436 0 to 1000 0.1 sec
1155h 04437 0 to 1000 0.1 sec
1156h 04438 0 to 1000 0.1 sec
1157h 04439 0 to 1000 0.1 sec
1158h 04340 0 to 1000 0.1 sec
Données du réseau
Registre
Plage
dec.
0, 1, 2
Res.