Hitachi SJ200-2 Manuel D'utilisation page 276

Masquer les pouces Voir aussi pour SJ200-2:
Table des Matières

Publicité

B–36
Liste des données ModBus
Code
Nom
Fonc.
B083 Carrier frequency
setting
B084 Initialization mode
(parameters or trip
history)
B085 Country code for initial-
ization (not accessible
to ModBus)
B086 Frequency scaling
conversion factor
B087 STOP key enable
B088 Restart mode after FRS
B090 Dynamic braking usage
ratio
B091 Stop mode selection
Groupe de fonction de réglage fin "B"
R/W
Description
R/W Sets the PWM carrier (inter-
nal switching frequency),
range is 2.0 to 14.0 kHz
R/W Select the type of initializa-
tion to occur, two option
codes:
00... Trip history clear
01... Parameter initialization
02... Trip history clear and
parameter initialization
Select default parameter
values for country on initial-
ization. Note: Write not
allowed from network.
R/W Specify a constant to scale the
displayed frequency for D007
monitor, range is 0.1 to 99.9
R/W Select whether the STOP key
on the keypad is enabled, two
option codes:
00... enabled
01... disabled
R/W Selects how the inverter
resumes operation when the
free-run stop (FRS) is
cancelled, two options:
00... Restart from 0Hz
01... Restart from frequency
detected from real speed of
motor (frequency matching)
R/W Selects the rate of use (in %)
of the regenerative braking
resistor per 100 sec. intervals,
range is 0.0 to 100.0%
0% . Dynamic braking
disabled
>0% Enabled, per value
R/W Selects how the inverter stops
the motor, two option codes:
00... DEC (decelerate and
stop)
01... FRS (free run to stop)
Données du réseau
Registre
Plage
hex
dec.
10D2h 04306
20 to
140
10D3h 04307
0, 1, 2
10D4h 04308
10D5h 04309 1 to 999
10D6h 04310
0, 1
10D7h 04311
0, 1
10D9h 04313
0 =
disabled
, 1 to
1000
enabled
10DA
04314
0, 1
h
Res.
0.1 Hz
0.1
0.1 %