Intended Use

The safety controller SK 35 can only perform its safety function if it is used correctly and integrated
into the process in a fail safe manner.
The intended use of the SK 35 is as a safety device in conjunction with safety contact mats, safety
bumpers or safety contact edges.
A different or enlarged use is not intended. The manufacturers does not assume liability for damages
and malfunctions caused by any misuse.
The manufacturer must permit the use in special applications.
Versions
Version SK 35-32
Polyamide enclosure in 22,5 mm width for 35 mm DIN-mounting rail assembly according EN 60715.
Supply voltage 230V 50/60Hz and 24 V AC/DC.
Version SK 35-82
Like version SK 35-32, however with supply voltage 115V 50/60Hz and 24V AC/DC.

Mechanical Mounting

The compact and assembly-friendly controller is to be mounted professionally on a 35 mm DIN
mounting rail in a dust and humidity-protected cabinet or enclosure with a protection class of at
least IP 54.
The installation position of the controller is not important.
Do not install the safety controller close to strong heat sources.