Accessory parts and Parts to be procured locally

Accessory parts
Part name
Q'ty
Shape
Installation
This
1
Manual
manual
Heat insulating
2
pipe
Installation
1
——
pattern
Banding band
2
Bushing
1
Refrigerant piping
• Piping material used for the conventional
refrigerant cannot be used.
• Use copper pipe with 0.8 mm or more thickness
for Ø6.4, Ø9.5, Ø12.7.
Use copper pipe with 1.0 mm or more thickness
for Ø15.9.
• Flare nut and flare works are also different from
those of the conventional refrigerant. Take out
the flare nut attached to the indoor unit of the air
conditioner, and use it.
Parts to be procured locally
Connecting pipe (Liquid side)
(6.4mm (diam.), Nominal (diam.) 1/4" thick 0.8mm)
MMC-AP0151H, MMC-AP0181H
(9.5mm (diam.), Nominal (diam.) 3/8" thick 0.8mm)
MMC-AP0241H to MMC-AP0481H
Connecting pipe (Gas side)
(9.5mm (diam.), Nominal (diam.) 3/8" thick 0.8mm)
MMC-AP0151H, MMC-AP0181H
(15.9mm (diam.), Nominal (diam.) 5/8" thick 1.0mm)
MMC-AP0241H to MMC-AP0481H
Power supply cord
2
Cable 3-core 2.5mm
, in conformity with Design 60245 IEC57
Usage
(Be sure to hand over to customers)
For heat insulation of
pipe connecting section
For confirmation of ceiling opening
and main unit position
For drain hose forming
For power supply cord profection
Part name
Q'ty
Heat insulator
1
Washer
4
Hose band
2
Drain hose
1
Heat insulator
1
<Separate sold parts>
Part name
Q'ty
Standard wired
1
remote controller
1
Shape
Usage
For heat insulation of
drain connecting section
For hanging-down unit
For connecting drain pipe
For drain piping
For sealing of piping hole
Shape
Usage
Model
RBC-AMT21E

Publicité