DITEC ENERGY 0DT828 Manuel D'installation page 25

Table des Matières

Publicité

IMPUT
Command
Function
1
2
N.O
Automatic closing
1
3
N.O
Opening
1
4
N.O
Closing
41
40
N.C
Reversal safety device
1
8
N.C
Reversal safety device
1
9
N.C
Stop
1
9
N.O
Non-pulse command
1
20
Partial opening
0
11
N.C
Closure limit switch
0
12
N.C
Limit switch slowdown
0
13
N.C
Opening limit switch
OUTPUTS
Output
1
+
24 V= / 0,5 A
0
-
LAMP
230 V~ / 50 W
24 V= / 1,2 A
-F
+F
200V= / 0.3 A
U W V
M
230 V~ / 6 A
3 ~
SEGNALAZIONI
LED
On
DL1
(2) Automatic closing
DL2
(3) Opening
DL3
(4) Closing
DL4
(9) Stop
DL5
(20) Partial opening
DL6
(40) Safety edge
KEYBOARD
ON
Starts the opening operation.
Starts the partial opening operation.
Starts and stops the STOP operation.
Starts the closing operation.
Adjustment limit switch
1.
Set the deceleration ramps to zero. (T5 - T6)
2.
Calibrate limit switch (C) on the geared motor so that the door stops
approximately 200-300mm from the closure point respectively.
3.
Calibrate limit switch (A), at the wished quote.
4.
Calibrate slowdown limit switch (B) in such a way that it engages at
approximately ¾ of the opening stroke.
5.
Calibrate the opening speeds using trimmer (T3) and closure (T4).
6.
Calibrate the opening (T5) and closure (T6) trimmers of the deceleration
ramps in such a way as to cause stopping in the actual door open and
door closed positions.
Permanently closing the contact enables automatic closing.
The closure of the contact activates an opening operation.
The closing manoeuvre starts when the contact is closed.
Opening the safety contact triggers a reversal of the movement (reopening) during a closing operation.
Opening the safety contact triggers a reversal of the movement (reopening) during a closing operation.
Opening the safety contact stops the current operation.
Permanently opening the safety contact enables the operation by non-pulse command
In this state, the opening (1-3/1-20) and closing (1-4) controls function only if held in the pressed position,
and the automation stops when the controls are released.
All safety switches, the step-by-step control and the automatic closing function are disabled.
The closing of the contact activates a partial opening operation of the duration set with the RP trimmer.
Once the automation stops, the partial opening control performs the opposite operation to the one
performed before stoppage.
The opening of the limit switch contact stops the closure operation.
The opening of the limit switch contact activates the slowdown in opening.
The opening of the limit switch contact stops the opening operation.
Value
Accessories power supply.
Power supply output for external accessories, including automation status lamp.
Flashing light (LAMP).
Activated during opening and closing operations.
Electric motor brake.
The output is active for the duration of both the opening and closing operation.
Three-phase motor.
Connect the contact of the motor circuit breaker in series to the limit switch.
Note: if the direction of rotation of the motor is incorrect for the desired direction of movement, swap the
L2 and L3 phases.
LED
DL7
Stop push button
DL8
(8) Closing Safety
DL9
(13) Opening limit switch
DL10
(12) Slowing down limit switch
DL11
(11) Closing limit switch
DL12
Flashing lamp
Button
Description
Description
On
DL13
DL14
DL15
DL16
DL17
The green LED on indicates the presence of the 24 V=power supply.
the red LED on indicates that the STOP has been activated.
the fl ashing red LED indicates that the safety devices have been activated.
- 25 -
LED
On
Run OK
Fault
Autotest
Brake
Cycles counter
LED
B
¾
C
300
0DT828 28/10/2010
EN
A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Energy

Table des Matières